Xiamen Teshow Co.,Ltd
+86-592-2225929 
ritazhousy@sina.com

1-phase SCR 120A

    详细说明

    Single Phase switching power regulator
    Features:
    1. Load voltage,single phase 24-380VAC(+/-10%)50/60HZ
    2. Work with all kinds of input:0-5VDC,0-10VDC,4-20mA,potentiometer
    3. Load options:40,75,80,120,150,175,200 amps
    4. Buffer circuit are built inside the unit to protect surge on the SCR
    5. Input,output,error indicatiores available on the panel for monitoring purpose
    6. All model with the same physical sizes
    7. Phase angled firing mode
    8. Black firs reardant housing with resin seal
    9. The unit mainly used for resisitive load


    Remark:TDD-220T120A,120A multiple inputs,220VAC soure single phase power regulators .220VAC load
    Note:You can order SCR only and purchase heatingsink and 
    cooling fans separately or we can sell complete kits with all 
    parts already put together in our plant
    Guidelins on the selection and usage of the voltage regulator
    1)Currentrating. as a general rule consider using the relay at 
    no more than 50% of its rated current for resistive load such 
    as a heater. lamps etc. 
    2)Heatsinks must always be installed together with the SSR 
    regardless of the load amps. natural convection cooling 
    might be sufficient in some cases depends on the site 
    situation.force air cooling must be taken into consider 
    under harsh conditions(contactour sales team for more info)
    3)Fast fuse must be installed in the system to protect overload 
    on the SSR 
    4)Silicon rubber pad or silicon compound must be applied to 
    the bottom of the SSR to help the heat radiation
    5)The SCR is 220V/380Vac load type,please choose correct 
    voltage based on your application6)This item is suitable for resistive load or very small inductive 
    load
    7)The screw for the input terminals has to be fastened 
    securely.otherwise extra heat will be generated and 
    accumulated on the screw and result the damage on the SCR
    8)Control cabinet should have sufficient air flow,which means 
    air flow in and out


    1. Power supply indicator,this indicator will light as long as 
    connect with power 220VAC or 380VAC
    2. input indicator,this indicator will light as long as connect with 
    4-20mA input
    3. Output indicator,this indicator will flash if output is 
    activated,the frequency of the flashing indicates the output 
    valve,flash faster means the output is higher,flash in lower 
    frequency means the output is lower4. COM5. CON+
    6. Internal 5V input (only used for potentiometer)
    next item: 1-phase SCR 75A
    Hot products

    Write To Us

    Please fill out the form and your request will be answered within one working day.